A reverse osmosis unit does not usually stop producing water in one day. The membrane loses output slowly, and the first signs are small changes that are easy to miss because the tap still works. Learning those signs early lets you schedule the service before the storage tank runs low at a bad moment.

The signs that show up first

The most common early sign is a slower refill of the storage tank. If the tank used to fill in a certain time after you drew water, and now takes noticeably longer, note the change. Another sign is a weaker drip at the RO faucet, even when the storage tank is full. A third sign is a drain line that runs for longer during each fill cycle than it did when the system was new.

Less obvious signs include a change in taste, especially when the storage tank is low, and a pressure gauge on the pre-filter housing that reads lower than it used to. Any of these can come from the membrane, the pre-filter or the storage tank, so the next step is to sort which one is the cause.

Keep a simple log instead of trusting memory

Keep a note near the unit with three entries: how long the tank takes to fill, how the faucet drip feels compared with last time, and what the pre-filter gauge reads when the system is at rest. Update it each time you notice a change. A short log is more useful at a service visit than a general description of the problem, because the tech can compare it with the last set of readings.

Check the pre-filters before you blame the membrane

Pre-filters load up with sediment and chlorine, and a loaded pre-filter slows the whole system. Check when the pre-filters were last changed, and look at the cartridge labels for the change interval. If the cartridges are overdue, change them and watch the fill time for a few cycles before you assume the membrane is failing. The membrane is the most expensive part, so it is worth ruling out the cheaper causes first.

What to ask the provider about the membrane

  • What is the membrane model, and what output or rejection level does the manufacturer use to mark end of life?
  • What is the service record for the pre-filters, and who keeps it?
  • If the membrane is replaced, does the quote include the pre-filters and the post-filter, and what are the exclusions?
  • Who will test the output after the change, and how will you see the result?

If you want to compare providers before you need service, the regional index lists the providers we have looked at, and the questions above are a good test of how a provider handles a decline call.